Heat Detector
The standard detector is 2-wire or 3-wire. For 4-wire type just add one relay output module. Simple and easy module placement enables wider application and flexible stoct control
Smoke Detector
Detector has a monitoring LED that operates about every 16 seconds (flash) during standby status. When there is smoke, the detector will issue fire signal after 16 consecutive confirmations.
Addressable Manual Call Point
- Address coding by dip switch.
- Emergency press alarm, immediately activates fire alarm signal.
- Phone jack and rest button behind the cover cap.
Addressable Resettable Manual Call Point
- Address coding.
- Red LED with current limiting resistor.
- Optional clear protection cover.
Smoke Detector
- Address coding by binary dip switch.
- High sound output 90dB(A) at 1 meter.
- Two wire connection with loop-powered.
- Maximum 30pcs of TBR9 per loop.
- Dustproof and waterproof IP65 rating.
Control Module
- Series with conventional devices to QA16 Panel.
- Designed to control input and output for all kinds of systems. (fire alarm, smoke evacuation, sprinkler, foam , winding door...etc.)
Conventional Fire Alarm Control Panel
QA12
- Model range from 1 to 32 zones.
- AC power supply has EMI (Electromagnetic Interference).
- Each zone has a separate disable function.
- Double sets of sounder contacts.
AH-03312
- Model range from 1 to 32 zones.
- AC power supply has EMI (Electromagnetic Interference).
- Each zone has a separate disable function.
- Double sets of sounder contacts.
Vivid32
- Model range from 1 to 32 zones.
- AC power supply has passed EMI (Electromagnetic Interference).
- Each zone has a separate disable function.
AH-02124 Annunciator
Simultaneously active function with the control panel, model nos. 5-QA12 and QA12-10L.
AH-02124 Annunciator (Repeater)
AH-02124 Annunciator (Repeater)
Addressable Fire Alarm Control Panel
QA16
- Each loop can connect up to 250 addressable devices. Maximum networking are 32 loops and total addressable points are 8000.
- Large LCD screen (40 x 15 lines) allows more events to be displayed on the same screen.
QA24 Annunciator
- Adopted RS485 communication mode and installed easily.
- Synchronous connection and the same operation interface with the control panel.
- The number of ALARM, WIRE-BREAK, FAULT events can display on LED synchronously.
QA124 Annunciator
- Adopted RS485 communication mode and installed easily.
- Synchronous connection and the same operation interface as control panel.
- Reviewable alarm, wire break, fault and history log datas.